684 research outputs found

    MICROBIAL HYDROLASES IMMOBILIZED ON POROUS MATRICES

    Get PDF
    Starch degrading enzymes are used as feed additives to increase the digestibility of corn meal based dietin livestock and poultry. To be efficient, these enzymes have to present a good activity and stability.Immobilization by physical bonding of enzymes on a porous support is a simple and efficient method topreserve enzyme molecules in an active form and retain their activity for a period of time.The aim of this study was to stabilize an enzymatic preparation with amylase activity produced by a nativestrain of Bacillus amyloliquefaciens in submerged culture. The immobilization technique used wasphysical bonding on a porous ceramic support. The enzymatic preparation with amylase activity was usedin immobilization in a liophylized form. By using the same method we immobilized also a purifiedAspergillus niger amylase. For both enzymes, the optimal temperature and pH of the native andimmobilized enzymes did not vary significantly. At temperature and pH values lower than the optimum,the relative activities have been higher for the immobilized Bacillus amyloliquefaciens enzyme comparedto the native one. The immobilization has led to an enzymatic compound with stability at pH 3 and 37°Cand in time higher than that of the free one

    Exponential dichotomies of evolution operators in Banach spaces

    Full text link
    This paper considers three dichotomy concepts (exponential dichotomy, uniform exponential dichotomy and strong exponential dichotomy) in the general context of non-invertible evolution operators in Banach spaces. Connections between these concepts are illustrated. Using the notion of Green function, we give necessary conditions and sufficient ones for strong exponential dichotomy. Some illustrative examples are presented to prove that the converse of some implication type theorems are not valid

    Endothelialization of a New Dacron Graft in an Experimental Model: Light Microscopy, Electron Microscopy and Immunocytochemistry

    Get PDF
    Two types of synthetic vascular grafts, Dacron Triaxial and Dacron Gelseal Triaxial, were implanted into both the common carotids of sheep. The animals were sacrificed 1, 2, 8, and 16 weeks after surgery. Multiple specimens, obtained from grafts and anastomoses, were studied by light microscopy, transmission and scanning electron microscopy. A parallel immunocytochemical analysis was performed on some specimens. Dacron Triaxial grafts failed to develop a complete neointimal coverage. Myofibroblasts and fibroblasts were the dominant cells in such synthetic graft. Moreover, focal areas of stripping, platelet deposition, and thrombosis were observed at 8 and 16 weeks. In contrast, a stable endothelial coverage developed on the Gelseal Triaxial grafts after 16 weeks

    Healing of Prosthetic Arterial Grafts

    Get PDF
    Numerous synthetic biomaterials have been developed as vascular substitutes. In vitro, ex vivo and in vivo studies have demonstrated that in animals, selected materials, i.e., Dacron and ePTFE (expanded polytetrafluoroethylene) grafts, are successfully incorporated in both the large and the small caliber host arteries through a process which is generally referred to as graft healing. Morphologically, this process consists of a series of complex events including fibrin deposition and degradation, monocyte-macrophage recruitment and flow-oriented cell-layer generation, this last event being the complete endothelialization of the arterial substitute. In contrast to experimental animals, the flow surface of synthetic vascular grafts remains unhealed in humans, particularly in the small caliber conduits. Healing in man consists of graft incorporation by the perigraft fibrous tissue response with a surface covered by more or less compacted, cross-linked fibrin. It is therefore obvious that: i) marked differences in graft healing exist between animals and man; and ii) the usual mechanisms of graft endothelialization are partially ineffective in man. In order to guarantee the patency of synthetic vascular grafts for human small artery bypass, new strategies and approaches have recently been attempted. In particular, the endothelial cell seeding approach has been successfully accomplished in animals and is being experimented in human clinical studies. The problems and results of this biological approach are outlined in this paper

    Development of a Rotation Device for Microvascular Endothelial Cell Seeding

    Get PDF
    A rotation device (RD) specifically designed to achieve sterile endothelial cell (EC) seeding of vascular grafts has been developed. The basic characteristics of the RD include: small dimensions, fully autoclavable components, and perfectly sealed graft holders. These features make it possible to maintain sterility during all the steps of EC seeding. This was documented by negativity of all bacteriological assays performed . Moreover, the RD can simultaneously support three vascular grafts with different lengths (20, 40, and 60 cm) and diameters (4-8 mm). EC seeding is performed in the climatized chamber (37 °C; 5 % C02) with constant rotation (0.1 -3 rpm). The rotation cycle can be completed automatically. The practical efficacy of the RD was investigated by seeding 2 x 105/cm2 of human microvascular EC on 20 cm length, 4 mm internal diameter (ID) fibronectin- coated polytetrafluoroethylene (ePTFE) grafts for 24 and 48 hours respectively . Further, the effect of a highly viscous plasma expander, i.e., haemagel, on cell retention was also evaluated. Results were not as favorable as expected. However, it should be emphasized that after 48 hours of eel! incubation by using the RD, 42 % of the initially seeded EC were still present and approximately 15 % were fully spread over the graft surface. Moreover, the 10 minute perfusion with haemagel did not decrease the number of adherent microvascular EC

    Long-term success of low-frequency subthalamic nucleus stimulation for Parkinson's disease depends on tremor severity and symptom duration

    Get PDF
    Patients with Parkinson's disease can develop axial symptoms, including speech, gait and balance difficulties. Chronic high-frequency (>100 Hz) deep brain stimulation can contribute to these impairments while low-frequency stimulation (<100 Hz) may improve symptoms but only in some individuals. Factors predicting which patients benefit from low-frequency stimulation in the long term remain unclear. This study aims to confirm that low-frequency stimulation improves axial symptoms, and to go further to also explore which factors predict the durability of its effects. We recruited patients who developed axial motor symptoms while using high-frequency stimulation and objectively assessed the short-term impact of low-frequency stimulation on axial symptoms, other aspects of motor function and quality of life. A retrospective chart review was then conducted on a larger cohort to identify which patient characteristics were associated with not only the need to trial low-frequency stimulation, but also those which predicted its sustained use. Among 20 prospective patients, low-frequency stimulation objectively improved mean motor and axial symptom severity and quality of life in the short term. Among a retrospective cohort of 168 patients, those with less severe tremor and those in whom axial symptoms had emerged sooner after subthalamic nucleus deep brain stimulation were more likely to be switched to and remain on long-term low-frequency stimulation. These data suggest that low-frequency stimulation results in objective mean improvements in overall motor function and axial symptoms among a group of patients, while individual patient characteristics can predict sustained long-term benefits. Longer follow-up in the context of a larger, controlled, double-blinded study would be required to provide definitive evidence of the role of low-frequency deep brain stimulation

    Measurement of shower development and its Moli\`ere radius with a four-plane LumiCal test set-up

    Get PDF
    A prototype of a luminometer, designed for a future e+e- collider detector, and consisting at present of a four-plane module, was tested in the CERN PS accelerator T9 beam. The objective of this beam test was to demonstrate a multi-plane tungsten/silicon operation, to study the development of the electromagnetic shower and to compare it with MC simulations. The Moli\`ere radius has been determined to be 24.0 +/- 0.6 (stat.) +/- 1.5 (syst.) mm using a parametrization of the shower shape. Very good agreement was found between data and a detailed Geant4 simulation.Comment: Paper published in Eur. Phys. J., includes 25 figures and 3 Table

    Spin alignment of K(892)±K^*(892)^\pm mesons produced in neutron-carbon interactions

    Full text link
    A new precise measurements of spin density matrix element ρ00\rho_{00} of K(892)±K^*(892)^{\pm} mesons produced inclusively in neutron-carbon interactions at \~60 GeV have been carried out in the EXCHARM experiment at the Serpukhov accelerator. The values of ρ00\rho_{00} obtained in the transversity frame are 0.424±0.011(stat)±0.018(sys)0.424\pm0.011(stat)\pm0.018(sys) for K(892)+K^*(892)^+ and 0.393±0.025(stat)±0.018(sys)0.393\pm0.025(stat)\pm0.018(sys) for K(892)K^*(892)^-. Significant PTP_T dependence of ρ00\rho_{00} has been observed in K(892)+K^*(892)^+ production.Comment: 8 pages, LaTeX, 3 eps figure

    Performance of fully instrumented detector planes of the forward calorimeter of a Linear Collider detector

    Get PDF
    Detector-plane prototypes of the very forward calorimetry of a future detector at an e+e- collider have been built and their performance was measured in an electron beam. The detector plane comprises silicon or GaAs pad sensors, dedicated front-end and ADC ASICs, and an FPGA for data concentration. Measurements of the signal-to-noise ratio and the response as a function of the position of the sensor are presented. A deconvolution method is successfully applied, and a comparison of the measured shower shape as a function of the absorber depth with a Monte-Carlo simulation is given.Comment: 25 pages, 32 figures, revised version following comments from referee
    corecore